Issue Description
we are U2000
Version : U2000V1R1C00CP311 to manage Huawei OSN3500 and OSN7500 , and we found
that the NE Datacollector Does not workingThe problem phenomenon as follow ( we have 2 problems ) :
1. After select the NE Datacollector from the OSN function tree , we could not login the the OSN NE in the NE data collector as showed in the b/m print screen
2. After select the NE datacollector from OSN
Function tree, we couldn't find Huawei OSN NE in the Datacollector ( OSN NE
not exist to select Login ) .
Alarm Information
Null
Handling Process
1. check if this problem in one NE or all NEs over
the U2000 .
2. check the U2000 System monitor process (espcially : neproxy process ) .
3. get these logs and sent it to GTAC :
* D:/U2000/server/tools/datacollector/dbfile/Datacollector.db
* D:/U2000/Client/Tools/neinfo.xml
4. check the Set Login account and check the Operated and fixed Users .
5. Check the Upper limit of creation from the datacollector logs if it reach to be 50 (the max ) let us use the temp solution till upgrade the U2000 version to be U2000 V1R2C01SPC100
2. check the U2000 System monitor process (espcially : neproxy process ) .
3. get these logs and sent it to GTAC :
* D:/U2000/server/tools/datacollector/dbfile/Datacollector.db
* D:/U2000/Client/Tools/neinfo.xml
4. check the Set Login account and check the Operated and fixed Users .
5. Check the Upper limit of creation from the datacollector logs if it reach to be 50 (the max ) let us use the temp solution till upgrade the U2000 version to be U2000 V1R2C01SPC100
Root Cause
For Problem # 1This problem is due to when your user login, other user resave it, then make this user logout.
Pls check NE--->set login Account, and check whether there has the same user set in this table, if yes, pls change fixed user to other login user. See following picture:
For Porblem # 2 : According to the Logs of the Datacollector we find that :
we find that : the creation NEs of Datacollector is
already reach the upper limit 50
so we need to upgrade current U2000 version to be U2000 V1R2C01SPC100 or use Temp solution as follow :
we can use the new (Datacollector.db) which supprot more 50 NE and replace the new (Datacollector.db) file in path
so we need to upgrade current U2000 version to be U2000 V1R2C01SPC100 or use Temp solution as follow :
we can use the new (Datacollector.db) which supprot more 50 NE and replace the new (Datacollector.db) file in path
Suggestions
1. check all the
U2000 system monitor .2. check the Set Login account in the Datacollector .
3. Use the Temp solution (use the new (Datacollector.db)) if you cannot upgrade the U2000 to be: U2000 V1R2C01SPC100
4. U2000 V1R2C01SPC100 of Higher version solves this problem.