How to Configure an SNMP Query Test Instance on Huawei Switch
Context
Before configuring an SNMP query test instance, configure an SNMP agent and ensue reachable routes between the NQA client and the SNMP agent.
You can obtain the statistics about communication between the NQA client and the SNMP agent.
Perform the following steps on the NQA client.
The configuration overview:
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
nqa test-instance admin-name test-name
An NQA test instance is created, and the NQA view is displayed.
Step 3 Run:
test-type snmp
The test type is set to SNMP.
Step 4 Run:
destination-address ipv4 ipv4-address
The destination IP address (IP address of the SNMP agent) is configured.
The SNMP function must be enabled on the destination host, otherwise, the NQA client cannot receive response packets.
Step 5 (Optional) Run the following commands as required to configure parameters for the SNMP test.
Run:
description string
A description is configured for the test instance.
Run:
frequency interval
The test period is set for the NQA test instance.
Run:
timeout time
The timeout period of a probe is set for the NQA test instance.
Run:
source-address ipv4 ipv4-address
The source IP address is configured.
Run:
source-port port-number
The source port number is configured.
Run:
ttl number
The TTL value in the NQA test packet is set.
Run:
sendpacket passroute
The NQA test instance is configured to send packets without searching the routing table.
Run:
probe-count number
The number of probes in a test is set.
Run:
tos value
Type of Service (ToS) is set for the test packet.
Run:
fail-percent percent
The failure percentage is set for the NQA test instance.
Run:
interval seconds interval
The interval at which test packets are sent is configured.
Run:
vpn-instance vpn-instance-name
The VPN instance name is configured.
Run:
records history number
The maximum number of historical records is set for the NQA test instance.
Run:
records result number
The maximum number of result records is set for the NQA test instance.
Run:
agetime hh:mm:ss
The aging time is set for the NQA test instance.
—-End
Note: this configuration also works for the Huawei s2700, Quidway S5700, s6700, Huawei S3700.