Issue Description
When the ODUK SPRING protection switching
is performed by running external commands, if the OTN Tributary board is
not in position, the switching may fail.
Alarm Information
Null
Handling Process
If the OTN board for the
westward or eastward services of the ODUK SPRING protection is not in position,
performing the switching by running external commands is nonsense. If you
really intend to perform the switching by running external commands, you must
ensure that the OTN board for services in that direction is in position.
Root Cause
configured between NE2 and NE6. In addition, the OTN board of NE2 is not in position.
Under normal
conditions, the service flow, indicated by the red real line, is as shown in
the figure. When NE6 starts a westward forced switching, NE2 switches from the
IDLE page to the eastward switching page. The service flow, indicated by the
blue dashed line, is as shown in the figure.
In the process of the switching, if the tributary board of NE2 is in position, the Huawei OTN signal on the protection link is stable and there are no abnormal alarms on the protection channel. But if the tributary board of NE2 is not in position, the OTN signal on the protection link needs to be regenerated by an NS2(OTN board according to certain Recommendations). The regeneration operation requires a certain period of time. The protection channel may detect abnormal alarms before the OTN signal regeneration is completed and immediately reports an SF alarm, which results in the failure of the forced switching.
In the process of the switching, if the tributary board of NE2 is in position, the Huawei OTN signal on the protection link is stable and there are no abnormal alarms on the protection channel. But if the tributary board of NE2 is not in position, the OTN signal on the protection link needs to be regenerated by an NS2(OTN board according to certain Recommendations). The regeneration operation requires a certain period of time. The protection channel may detect abnormal alarms before the OTN signal regeneration is completed and immediately reports an SF alarm, which results in the failure of the forced switching.
Suggestions
Null