Showing posts with label U2000 license. Show all posts
Showing posts with label U2000 license. Show all posts

Tuesday, October 31, 2017

Commissioning Optical Power of OTU Board

The overload of the APD receiver laser is -9 dBm. If the input optical power is higher, the APD laser may be damaged. Therefore, it is recommended that you insert the fiber loosely from the input optical port of the OTU during commissioning. After commissioning, make sure the input optical power is lower than the receiver overload before you insert the fiber.


Forcing the OTU Board to Emit Light

This section describes how to force the OTU board to emit light.

Prerequisites

The NE must be created on the U2000.

Tools, Equipment, and Materials

U2000

Background Information

The signals accessed on the client side or the WDM side should be service signals in actual transmission, or the optical signals generated by forcing the board to emit light.
The WDM side of the OTU board by default is forced to emit light. If it does not emit light, refer to the following procedure to query whether the board is forced to emit light. If the board is not forced to emit light, set the board to emit light.

Precautions

  • The prerequisite for commissioning the ESC (Electric Supervisory Channel) is that the OTU is forced to emit light.

Procedure

  1. In the NE Explorer window, select the desired OTU and choose Configuration > WDM Interface from the Function Tree.
  2. Select Channel from the drop-down list.
  3. Optional: Click the Basic Attributes tab. Set the Automatic Laser Shutdown of the optical port on the WDM side of the OTU to DISABLE.
    Only the LWX2, LWXD and LWXS can set Automatic Laser Shutdown of the WDM side.
  4. Set the Laser Status of the optical port on the WDM side of the OTU to OPEN.
  5. Click Apply.

Adjusting the Input Optical Power of OTU Board

ools, Equipment, and Materials

Optical power meter

Precautions

Before the equipment is powered on, verify that the fixed optical attenuator is configured according to the configuration rules. Verify the input optical power of the OTU (including the WDM side and client side) is lower than the receiver overload to avoid damage to the optical module during commissioning. Note that the overload of the APD receiver laser is only -9 dBm. Adjust the input optical power at the IN port on the WDM side of the OTU to ensure that the input optical power is within the optimal range: from -14 dBm to -25 dBm.For the specifications about the sensitivity and overload point of the OTU board.

Commissioning Requirements

  • Adjust the input optical power at the IN port on the WDM side of the OTU to ensure that the input optical power is within the optimal range: from -12 dBm to -5 dBm; adjust the input optical power at the RXn port on the client side of the OTU to ensure that the input optical power is within the optimal range: from (sensitivity +3) dBm to (overload point -2) dBm.
  • Confirm the optical preamplifier on the WDM side of the OTU at the receive end has output the standard optical power of single wavelength. When this occurs, the input optical power on the WDM side can be adjusted based on the actual optical power by adding, changing or removing the fixed optical attenuators.
  • After commissioning, insert a fiber into the input optical port on the OTU when the input optical power reaches a normal state.

Tuesday, June 20, 2017

I Want to Reset Huawei OLT MA5600T Password, Then How Should I Do?

My Huawei OLT MA5600T Password is known by others, so I need to reset the password, then how should I do?

After using the device, the user may change the default user name and password. If you forget the password of user root, please perform the following methods. Method 2 is recommended.

Method 1: Load the empty database matched the device again through DoS. After restarting the device, log in to the system by using the default root password admin (OLT) or mduadmin (MDU). This method will lead to loss of data configurations and the user needs to configure the data again.

Method 2: Modify the configuration file using the U2000.

1. On the U2000, choose Administration > NE Security Management > LCT User Management from the main menu.

2. On the LCT User Management tab page, select NE User and then Device Type. Select the desired device name from the Device Name column and user name from the Name column. In the displayed dialog box, choose Set Password to set the new password.

This method does not require a device restart or services are not interrupted. 
Method 3: If the device is managed by the NMS, modify the configuration file on the NMS as follows: 
1. Back up the configuration file of the device on the NMS. 
2. Open the configuration file and find out the record of changing the root password, as shown in boldface in the following display. 
3.[MA5600V800R0013: 6888] 
4.# 
5.[global-config] 
6.
7.  <global-config> 
8.
9. terminal user name buildrun_new lww231 *[)!AAYS*Y&aU86K;V-a@AUA!!* 1 2015:06:0410.11.:17:07:25 2015:06:04:17:07:25 root 2 6 ----- 
12.
13. terminal user name buildrun_new bmsmpls *[4P]`OUIa%=[G]0U3=OWJY1!!* 0 2015:06: 
14.
15.08:15:01:02 2015:06:08:15:01:02 root 3 65535 ----- 
16.
17.adsl mode switch-to ADSL 
18.19.vdsl mode switch-to normal20.Delete the boldface part and then save the configuration file. 
21.Load the modified configuration file to the system through the NMS and activate the configuration file. 
22.Log in to the device by using the default root password admin (OLT) or mduadmin (MDU)