Showing posts with label MA5800 X17. Show all posts
Showing posts with label MA5800 X17. Show all posts

Wednesday, November 8, 2017

GPHF 16-port GPON OLT interface board On Huawei MA5800 X2, MA5800 X7, MA5800 X15, MA5800 X17


GPHF board is a 16-port Huawei GPON OLT interface board. It works together with the ONU to provide the GPON access service.



GPHF High density and energy saving

  • High density and low power consumption, supporting 2048 access users
  • Manual shutdown of idle PON ports, preventing power waste
  • A maximum distance difference of 40 km between two ONUs under the same PON port, simplifying network planning
  • Intelligent management channel
  • 4-level HQoS, improving user experience
  • 9216 jumbo frames, greatly improving transmission efficiency
  • Efficient OAM
  • Real-time rogue ONU detection and isolation, ensuring stable service running
  • Variable-length of OMCI, improving upgrade efficiency and reducing break off time
  • 1:64 eOTDR, supporting accurate fault demarcation and quick fault locating

16 GPON ports
Max. split radio:
Class B+: 1:64
Class C+/C++: 1:128


Thursday, August 17, 2017

How to Measure the Transmit Optical Power of an Huawei OLT PON Port?

Check whether the optical module on a PON port of the OLT works properly by measuring the transmit optical power.

Prerequisites

  • The OLT is powered on.
  • The PON board is in the normal state.
  • The PON port is enabled.

Tools, Meters and Materials

  • Single-mode fiber jumper with the SC/PC connector. No longer than 1 m. Best to use new jumper.
  • Burst optical power meter or ordinary optical power meter.

Impact on the System
When the transmit optical power of a PON port on Huawei OLT is measured, the PON port will fail to transmit any service.

Precautions
Before or after measuring the optical power, you need to clean the connector of the optical fiber. This is because if a contaminated optical fiber is connected to a normal optical fiber connector, the connector will be contaminated, which leads to abnormal attenuation and reflection and thus affecting optical path quality.

Procedure
Step 1 Configuring the measure parameters of the optical power meter.
Unit of optical power: dBm
Wavelength: 1490 nm
Step 2 Connect the optical power meter directly to the optical module on the OLT PON port using optical fiber jumper, as shown in Figure The value on the optical power meter is the transmit optical power of Huawei OLT MA5800 PON port.
  • If the value on the optical power meter changes within a range of 0.2 dBm, take the average value.
  • If the value on the optical power meter changes in a range wider than 0.2 dBm, then it is possible that the fiber is not properly connected, the fiber is excessively bent, or the fiber connector has dust.
  • Do not bend the fiber. A bent fiber may affect the test result.
Step 3 Compare the test result with the optical module parameters of the corresponding board in the hardware description.