OSN1500B Glod Line Configuration Including:
- OSN1500B Subrack, with 1+1 PIU, 1PCS AUX
- 2 PCS Q2CXL16 Equipped, Support Cross-Connect and Main Control 1+1 Redundancy, and Provide 2*STM-16 Optical Interface, Transmission Distance 15KM.
- 1 PCS EFS0+ETF8 Equipped, Support 8*FE Electrical Interface.
- 1 PCS SLQ4(S-4.1) Equipped, Support 4*STM4 Optical Interface, transmission distance 15KM.
- 1 PCS R1SLQ1(S-1.1) Equipped at half slot, Support 4*STM1 Optical Interface, transmission distance 15KM.
- 1 PCS R2PD1+D75S Equipped at half slot, Support 32*E1 75ohm Service Access.
- Cross-Connect Capacity is 20G/High order, 20G/Low order.
- System Software Loaded by default, Version Available at V1R8 or V1R10.
- SFP Module for Optical Interface can be Swappable to Support Longer Transmission Distance.
- E1 Cable for R2PD1 is not included.Huawei OSN1500B Gold Line Configuration, is a recommended board bundle provided by Thunder-link.com, it has most common service type and ordinary ports. You can find other configuration bundle at CONFIGURE page, where you can even configure by yourself by selecting the boards you need. If you need customized configuration, please contact with Thunder-link.com Sales Team. who will come back to you shortly.
Q: What is the slot access capacity?
A: Before slot division of the OptiX OSN 1500B:
In the OSN 1500B subrack, slots 11-13 can be divided into half-width slots. Slot 11 can be divided into two half-width slots numbered slot 1 and 11, slot 12 can be divided into two half-width slots numbered slot 2 and 12, and slot 13 can be divided into two half-width slots numbered slot 3 and 13.
Q: What boards are applicable on OSN1500B?
A:
List of cross-connect board | |
R1PCXLN | SCC unit, cross-connect unit, optical interface unit integrated board |
List of packet processing boards | |||
Q1PEGS2 | 2xGE processing board | R1PEF4F | 4xFE optical processing board |
R1PEGS1 | 1xGE processing board | R1ML1 | Multi-protocol 16xE1 electrical processing board |
R1PEFS8 | 8xFE processing board |
List of List of SDH boards | |||
N3SL16, N3SL16A | 1xSTM-16 optical interface board | N1SF16E | 1xSTM-16 optical interface board (with the outband EFEC function) |
N1SL16,N1SL16A, N2SL16,N2SL16A | 1xSTM-16 optical interface board | N3SLQ41 | 4xSTM-4/STM-1 optical interface board |
N1SF16 | 1xSTM-16 optical interface board (with the outband FEC function) | N1SLQ4, N2SLQ4 | 4xSTM-4 optical interface board |
N1SLQ4A | 4xSTM-4 optical interface board | N1SLD4, N2SLD4, N1SLD4A | 2xSTM-4 optical interface board |
R1SLD4 | 2xSTM-4 optical interface board (divided slot) | R1SL4 | 1xSTM-4 optical interface board (divided slot) |
N1SL4, N2SL4, N1SL4A | 2xSTM-4 optical interface board | N1SLT1 | 12xSTM-1 optical interface board |
N1EU08 | 8xSTM-1 electrical interface board | N1OU08((LC) N2OU08(SC) | 8xSTM-1 optical/electrical interface board |
N2SLO1, N3SLO1 | 8xSTM-1 optical interface board | N1SLQ1, N2SLQ1 | 4xSTM-1 optical interface board |
N1SLQ1A | 4xSTM-1 optical interface board | R1SLQ1 | 4xSTM-1 optical interface board (divided slot) |
N1EU04 | 4xSTM-1 electrical interface board | N1SEP1 | 2xSTM-1 when interfaces are available on front panel.8xSTM-1 when interfaces are available on corresponding interface board |
N1SL1, N2SL1, N1SL1A | 1xSTM-1 optical interface board | R1SL1 | 1xSTM-1 optical interface board (divided slot) |
List of List of PDH board | |||
N1SPQ4 | 4xE4/STM-1 electrical processing board | N2SPQ4 | 4xE4/STM-1 electrical processing board |
N1MU04 | 4xE4/STM-1 electrical interface board | N2PQ3 | 12xE3/T3 service processing board |
N1D34S | 6xE3/T3 electrical switching interface board | N1C34S | 3xE3/T3 electrical switching interface board |
N1PD3, N2PD3 | 6xE3/T3 service processing board | N1PL3, N2PL3 | 3xE3/T3 service processing board |
N1PL3A, N2PL3A | 3xE3/T3 service processing board (Interfaces are available on the front panel.) | N1PQ1 | 63xE1 service processing board |
N2PQ1 | 63xE1 service processing | N1PQM | 63xE1/T1 service processing board |
N1D12B | 32xE1/T1 electrical switching interface board | N1D12S | 32xE1/T1 electrical switching interface board (120 ohms) |
N1D75S | 32xE1 electrical switching interface board (75 ohms) | R1PD1, R2PD1 | 32xE1 service processing board |
R1PL1 | 16xE1 service processing board | N1PFL1 | 8xE1 optical processing board |
N1TSB8 | 8-port electrical switching interface board | N1TSB4 | 4-port electrical switching interface board |
N1DX1 | DDN service accessing and converging board | N3DX1 | DDN service accessing and converging board |
N1DXA | DDN service converging and processing board | N1DM12 | DDN service interface board |
List of EoS boards | |||
N1EFT8,N2EFT8 | 8xFE/16xFE transparent transmission board | N1EFT8A, N2EFT8A | 8xFE transparent transmission board |
N1EFS0A | 16xFE switching and processing board | N1EFS0,N2EFS0, N4EFS0, N5EFS0 | 8xFE switching and processing board |
N1EFS4, N2EFS4, N3EFS4 | 4xFE switching and processing board | R1EFT4, R2EFT4 | 4xFE transparent transmission board (divided slot) |
N1EMS4 | 4xGE and 16xFE switching and processing board | N1EMS2 | 2xGE and 16xFE switching and processing board |
N1EGS4, N3EGS4 | 4xGE switching and processing board | N1EGT2, N2EGT2 | 2xGE transparent transmission board |
N2EGS2, N3EGS2 | 2xGE switching and processing board | N1EFF8,N1EFF8A | 8x100M Ethernet optical interface board |
N1ETF8,N1ETF8A | 8x100M Ethernet twisted-pair interface board | N1ETS8 | 8x10/100M Ethernet twisted pair interface switching board |
List of ATM boards | |||
N1ADL4, N1IDL4 | 1xSTM-4 ATM service processing board | N1ADQ1, N1IDQ1 | 4xSTM-1 ATM service processing board |
List of RPR boards | |||
N2EGR2 | 2xGE ring processing board | N2EMR0 | 12xFE and 1xGE ring processing board |
List of RPR boards | |||
N1VST4 | 4-port video service transparent transmission board | N1MST4 | 4-port multi-service transparent transmission board |
List of RPR boards PCM boards | |||
N1FXSO12 | 12-port FXS/FXO processing board | N1FXS12 | 12-port FXS processing board |
N1FXO12 | 12-port FXO processing board | N1AT6 | 6-port 2/4 wire and E&M processing board |
Lost of WDM board | |||
TN11CMR4 | 4-channel optical add/drop multiplexing board | N1MR2C,N1MR2B | 2-channel optical add/drop multiplexing board |
TN11CMR2, TN11MR2 N1MR2A | 2-channel optical add/drop multiplexing board | TN11MR2 | 2-port optical add/drop multiplexing board |
TN11MR4 | 4-port optical add/drop multiplexing board | N1CMD2 | 2-channel bidirectional optical multiplexer and demultiplexer board |
N1LWX | Arbitrary bit rate wavelength conversion board | N1FIB | Filter isolating board |
List of auxiliary boards | |||
R1EOW | Orderwire processing board | R1AUX, R2AUX | System auxiliary interface board |
R1AMU | Orderwire processing or alarm cascading board | R1FAN | Fan board |
List of optical amplifier boards | |||
N1BPA | One-channel power amplifier and one-channel pre-amplifier board | N2BPA | One-channel power amplifier and one-channel pre-amplifier board |
N1BA2 | Two-channel power amplifier board | N1COA, 61COA, 62COA | Case-shaped optical amplifier |
N1RPC01 | Forward Raman driving board (external) | N1RPC02 | Backward Raman driving board (external) |
List of power boards | |||
UPM | Uninterruptible power module | R1PIU,R1PIUB | Power interface board |
Q: Can I use new version board to replace old version ones?
A: Yes, most of OSN1500B service board, you can use newer version to replace old ones, here listed some ordinary substitution boards below, or you can contact Thunder-link.com technical sales team to confirm the board substitution relation.
Substitute Board | To-Be-Substituted Board | Substitute Board | To-Be-Substituted Board |
N1SL1A | N1SL1 | N1SL4A | N1SL4 |
N1SLD4A | N1SLD4 | N1SLQ1A | N1SLQ1 |
N1SLQ4A | N1SLQ4 | N3SL16 | N1SL16 |
N3SL16A | N1SL16A | N3SLQ41 | N1SLQ1 N1SLQ4 N2SLQ1 N2SLQ4 |
N2PD3 | N1PD3 | N2PL3 | N1PL3 |
N2PL3A | N1PL3A | N2PQ1 | N1PQ1 |
N2SPQ4 | N1SPQ4 | N2EFS0 | N1EFS0 |
N2EFS4 | N1EFS4 | N2ETF8 | N1ETF8 |
N2EFT8A | N1EFT8A | R2EFT4 | R1EFT4 |
N2EGT2 | N1EGT2 | N3EFS4 | N1EFS4 N2EFS4 |
N3EGS2 | N1EGS2 N2EGS2 | N4EGS4 | N3EGS4 |
N5EFS0 | N1EFS0 N2EFS0 N4EFS0 |
Q: Is there any restrictions for board substitution?
A: Yes, there list some restrictions when board substitution below or you can contact Thunder-link.com technical sales team to confirm the board substitution relation.
Board that supports board version replacement functions | Board that cannot Be substituted | Condition |
N1SL16A | N2SL16A N3SL16A | The TCM function is enabled for the N2SL16A/N3SL16A. |
N3SL16 | N2SL16 | The TCM function is enabled or AU-3 services are configured for the N2SL16 |
N3SL16A | N2SL16A | AU-3 services are configured for the N2SL16A. |
N3SLO1 | N2SLO1 | AU-3 services are configured for the N2SLO1. |
N2EFS0, N4EFS0 | N1EFS0 | N1EFS0 is configured with QoS functions. If an N4EFS0/N2EFS0 is configured as N1EFS0 and the simulation package loading method is used, the board software of N1EFS0 is loaded. As a result, a cold reset is performed on the board and board version replacement function becomes ineffective. Therefore, an N4EFS0/N2EFS0 must not be configured as an N1EFS0. |
N4EFS0 | N2EFS4 | If an N4EFS0 is configured as an N2EFS0 and the simulation package loading method is used, the board software of the N2EFS0 is loaded. As a result, a cold reset is performed on the board and the board version replacement function becomes ineffective. Therefore, an N4EFS0 must not be configured as an N2EFS0. |
N2EGS2 | N1EGS2 | The N1EGS2 is configured with QoS functions. |
Q: Do you have U2000 NMS if I buy OSN1500B from you?
A: Yes, we can share U2000 software package to our customers for free.
Q: Do you have U2000 NMS License if I buy OSN1500B from you?
A: Yes, we provide to our customer U2000 license for test purpose, not for commercial use.
Q: Does OSN1500B have AC power supply?
A: No, OSN1500B power interface unit PIU is DC -48V input only, if you need a AC/DC power converter, please contact with Thunder-link.com sales team.
Q: Do you offer OSN1500B Subrack separately?
A: Yes, please contact with our sales team for details.
No comments: