Method 2
Use the SMARTKIT inspector to query all optical modules. Manually collect information about vendor PN, transmit optical power, and enclosure temperature in the query results, as shown in Figure 2.
Characteristics of the involved optical module: The temperature is higher than 60 degrees, the transmit optical power is not in the range from 1.5 dBm to 5 dBm, the vendor PN is SPS4348HHPCDE, and the vendor is SOURCE PHOTONICS.
[Root Cause]
Some optical modules may rarely become faulty after long-term working at high temperature, resulting in unstable transmit optical power.
[Impact and Risk]
When the problem occurs, corresponding ONUs are offline. According to the vendor, 0.143% of the optical modules may become faulty at high temperature.
[Measures and Solutions]
Recovery measures:
Perform the following steps to cool the enclosure of the involved optical module.
Tune down the temperature in the equipment room.
If dust on fans or subracks results in weak heat dissipation capacity, urge customers to clear the dust. For details, customers can refer to corresponding product documentation, such as the MA5600T&MA5603T V800R011C00 Product Documentation 03.
Manually accelerate the rotating speed of fans. (Long-term high-speed rotation shortens the useful life of a fan, so this solution is just a temporary solution.) Setting examples are as follows:
For V800R005/V800R006/V800R007/V800R008:
MA5600T(config)#interface emu 0
MA5600T(config-if-fan-0)#fan speed mode manual
MA5600T(config-if-fan-0)#fan speed adjust 5
For V800R009/V800R010/V800R011/V800R012:
MA5600T(config)#diagnose
MA5600T(diagnose)%%fan speed mode manual 6
The digit in red in the command indicates the rotating speed level of the fan (the highest levels for V800R008 and V800R011 are 5 and 6 respectively), the higher the digit, the faster the rotating speed. It is recommended to tune up the rotating speed to the maximum, and then gradually tune it down. Long-term high-speed rotation shortens the useful life of a fan. Therefore, exercise caution when adopting this solution.
Preventive measures:
Use the preventive maintenance inspection tool to check the enclosure temperature of optical modules on the live network. For the site where the enclosure temperature of optical modules is higher than 60 degrees, urge customers to improve equipment room environment. The recommended temperature is about 23 (±1) degrees.
Solution:
When the problem occurs, perform the recovery measures to cool involved optical modules, and then perform the following steps based on actual situations:
If the problem is solved, the optical module can be used but not used at high temperature.
If the problem persists (the hardware of the optical module is faulty), use a spare part to replace it. A small number of faulty optical modules can be directly sent to Huawei for repair based on the specified procedure. A large number of faulty optical modules are handled by corresponding regional service contact personnel.
The warning does not take effect when the trigger conditions are not met.
[Attachment]
None
No comments:
Post a Comment