Monday, March 6, 2017

Where to Find the Corresponding for the Error Codes Carried by Response in the Package Capturing

Issue Description
Q:
Where to find the corresponding Chinese description for the error codes carried by response in the package capturing?
Alarm Information
Null
Handling Process
A:
As for the V200R008 network management version, the mapping of most error codes can be found in the table of bms_NMSErrCode in BMSDB database. For those error codes that cannot be found in this table, confirm with the R&D of the host.
The following commands can be run:
1>select * from bms_NMSErrCode                                                    
2> go    
iDevType    iModuleID   iDeviceErrCode  iNMSErrCode        strErrDesc
-2           0            -18          1610612809.000000            
Illegal address
In this table, two fields of iDeviceErrCode and strErrDesc exist: The former one is the error code returned by the equipment and the latter one is the corresponding interpretation.
Root Cause
Null
Suggestions
Null
 The most popular Huawei S2700EI switch as below:

LS-S2700-9TP-SI-AC

Huawei S2300 series switch (4)

S2350-EI

Version Mapping

Port Description

10/100BASE-TX Ethernet Electrical Port


1000BASE-X Ethernet Optical Port

When a 1000BASE-X port uses a GE optical module, it can only transmit and receive data at
1000 Mbit/s and does not support the 100 Mbit/s transmission speed. When a 1000BASE-X port
uses a GE copper module, it can transmit and receive data at 10 Mbit/s, 100 Mbit/s, or 1000
Mbit/s.

Combo Port
A combo port consists of an optical Ethernet port and an electrical Ethernet port on the panel.
Each combo port matches only one internal forwarding port. The electrical and optical ports of
a combo port are multiplexed, and only one of them can work at a time. When one of the Ethernet
ports is working, the other port is shut down.

JTAG port
\

Power Supply Configuration
PoE Power Supply Configuration
In the S2350-EI series, the S2350-20TP-PWR-EI-AC and S2350-28TP-PWR-EI-AC are PoE
models. Both the two models use an internal AC power module, which provides 370 W of PoE
power. The S2350-28TP-PWR-EI-AC can provide full PoE power (IEEE 802.3af) to 24 ports
and full PoE+ power (IEEE 802.3at) to 12 ports. The S2350-20TP-PWR-EI-AC can provide full
PoE power to 16 ports and full PoE+ power to 12 ports.

Non-PoE Power Supply Configuration
The non-PoE models in the S2350-EI series use internal power modules and do not support
pluggable power modules.

The most popular Huawei S2700EI switch as below:

LS-S2700-9TP-SI-AC

Telephone: 852-30623083
           Supports@Thunder-link.com            


Thursday, March 2, 2017

Huawei S2300 series switch (3)

Huawei S2300-EI Switch

Version Mapping
Mappings between the S2300-EI series switches and software versions
S2309TP-EI-AC: V100R002 to V100R006C05
S2309TP-EI-DC: V100R002 to V100R006C05
S2309TP-PWR-EI: V100R003 to V100R006C05
S2318TP-EI-AC: V100R002 to V100R006C05
S2318TP-EI-DC: V100R002 to V100R006C05
S2326TP-EI-AC: V100R002 to V100R006C05
S2326TP-EI-DC: V100R002 to V100R006C05
S2326TP-PWR-EI: V100R003 to V100R006C05
S2328P-EI-AC: V100R006C05
S2352P-EI-AC: V100R002 to V100R006C05
S2352P-EI-DC: V100R002 to V100R006C05

Port Description

10/100BASE-TX Ethernet Electrical Port
A 10/100BASE-TX Ethernet electrical port sends and receives service data at 10/100 Mbit/s,\
Attributes of a 10/100BASE-TX Ethernet electrical port

100/1000BASE-X Ethernet Optical Port
A 100/1000BASE-X Ethernet optical port receives and sends service data at 100/1000 Mbit/s.
Attributes of a 100/1000BASE-X Ethernet optical port

1000BASE-X Ethernet Optical Port
Attributes of a 1000BASE-X Ethernet optical port
Console Port
Attributes of a console port
Power Supply Configuration
PoE Power Supply Configuration
In the S2300-EI series, the S2309TP-PWR-EI and Huawei S2326TP-PWR-EI are PoE models.
The S2309TP-PWR-EI has a built-in power module that can provide 124 W of PoE power. It
can provide full PoE power (15.4 W) in compliance with IEEE 802.3af on a maximum eight
ports or full PoE+ power (30 W) in compliance with IEEE 802.3at on a maximum of four ports.
The S2326TP-PWR-EI has two power module slots, each of which can have a 500 W or 250
W power module installed. A power module can provide 369.6 W or 123.2 W of PoE power for
powered devices (PDs).

Non-PoE Power Supply Configuration
The non-PoE models of Huawei S2300-EI series have a built-in AC power module and do not support pluggable power modules.

Heat Dissipation




Wednesday, March 1, 2017

Huawei S2300 series switch (2)

Huawei S2300-SI switch:

Series Model Available Version

S2309TP-SI: V100R002 to V100R006C05
S2318TP-SI: V100R002 to V100R006C05
S2326TP-SI: V100R002 to V100R006C05

Appearance and Structure
Appearance of the S2309TP-SI



















Appearance of the S2318TP-SI









Appearance of the S2326TP-SI



















Port Description

10/100BASE-TX Ethernet Electrical Port
A 10/100BASE-TX Ethernet electrical port sends and receives service data at 10/100 Mbit/s,
and must use.
Attributes of a 10/100BASE-TX Ethernet electrical port

















Combo Port
A combo port consists of an optical Ethernet port and an electrical Ethernet port on the panel.
Each combo port matches only one internal forwarding port. The electrical and optical ports of
a combo port are multiplexed, and only one of them can work at a time. When one of the Ethernet
ports is working, the other port is shut down.
Console Port
The console port of a switch can connect to an operation terminal for onsite configuration. The
port must use
Attributes of a console port









Tuesday, February 28, 2017

Huawei S2300 series Switch (1)

Chassis Overview

Huawei S2300 series Ethernet switches integrate the access and transmission functions to provide
reliable access/aggregation and high-quality transmission of services on wide area networks.
The switches are built on an integrated hardware platform, and the hardware system consists of
the chassis, power module, fan module, and Switch Control Unit (SCU).

The S2300 series are available in a variety of models for you to choose based on your network
requirements.

The S2300 series includes the S2300-SI, S2300-EI (S2309TP-EI-AC), and S2350-EI subseries, all of which are Layer 2 switches.

Naming Conventions

S2350-20TP-PWR-EI-AC
ABC D E F G H I
S2326TP-SI

ABC E F H


More related:

MA5600T Multicast Feature Glance
MA5600T Series Maintenance Feature Glance
MA5600T&MA5603T&MA5608T 10G GPON Feature Glance
How to Configure the H.248-based Voice Service?
How to Login Huawei Equipment Through the Local Serial Port



Monday, February 27, 2017

BMS R11 TL1 create ONT with error in SQL

Issue Description
When the customer tries to create Huawei ONT trough TL1 in BMS R11, there is SQL error:
ADD-ONT::DEV=PRT45-1_OLT-HW_1,FN=0,SN=1,PN=0,ONTID=1:44422::NAME=devil,ALIAS=djdj,CAPABPROF=ONT_PROFILE_HW_HG850,SERIALNUM=2011-2E0A4C41, AUTH=SN,ALMPROF=alarm-profile_1;
    0 2008-04-11 14:12:00
M  SN COMPLD
   EN=1610614891   ENDESC=Failed to execute SQL
Eventhough, the ONT is created:
OLTHW-TestPLant1(config-if-gpon-0/1)#display ont info 0 1
  ----------------------------------------------------------------------------
  F/S/P           : 0/1/0
  ONT-ID          : 1
  Control flag    : active
  Run state       : up
  Config state    : normal
  Match state     : match
  DBA type        : SR
  Loop mode       : disable
  ONT RTD(us)     : -
  Transparent     : disable
  Ont Profile ID  : 6
  Authentic type  : SN-auth
  SN              : 323031312E0A4C41(2011-2E0A4C41)
  Description     : ONT_NO_DESCRIPTION
  Alarm profile-ID: 1
  ----------------------------------------------------------------------------
  ----------------------------------------------
  T-CONT-ID     DBA-profile     Alloc-ID
  ----------------------------------------------
          0               1            1
- ----------------------------------------------
This problems seems to happen in the case we had previously an ONT with the same ONT_ID in the same port.
If we create the Huawei ONT with a ONT_ID that was never used, the problem does not happen.
It seems that when we delete the ONT in the BMS, some information is not deleted in one of the tables.
      
Alarm Information
Null
Handling Process
CLI deleting leads to in-consistence between the device and BMS, syn can solve the problem.
Root Cause
Null
Suggestions
 Null
More related:

Telephone: 852-30623083
           Supports@Thunder-link.com            




Sunday, February 26, 2017

The Service port Cannot Display Normally When Double-clicking the MA5600 Network Element to Enter the Board

Issue Description
Q: 
In the NMS topology, the serviceport cannot display normally when double-clicking the network element to enter the board.
Alarm Information
Null
Handling Process
A:
The status of Huawei MA5600 serviceport is the status of the traffic. Only when the single end PVC, the state machine of the traffic and the ADSL port are all  in Up status, the status of the serviceport is Up. Click the Synchronize Network Element in the Serviceport in the Serviceport Plane.




If the board is in position, generally the status of the single end PVC is Up.
The status of the ADSL port is Up after connecting to the modem.
The status of the service port is Up, indicating the normal condition.
Root Cause
1. The MA5600 database is full and the data space and the log space are normal.
2. MA5600 process is abnormal and no boot record. 
3. Other ports of Huawei MA5600 are normal. Only the service port is abnormal.
4. The MA5600 version is matched with the NMS version.
Suggestions
Null